Filter Results By:
Products
Applications
Manufacturers
kVA
Is a Kilovolt-ampere rated uninterruptable power supplies.
-
product
10-amp AC and DC Variable Power Supply
ACDC-10
The ETI Model ACDC-10 is a small, lightweight, and portable AC and DC power supply. The unit is intended for resetting circuit breaker charging motors and other general-purpose applications. It will provide DC voltage in three nominal ranges from 0-120V, 240V, and 480V at 1 kVA, as well as AC voltage in three nominal ranges from 0-140V, 280V, and 560V at 1.4 kVA. The ACDC-10 is housed in a rugged plastic enclosure approximately 20” x 11” x 18” and weighs less than 65 lbs
-
product
Three-Phase AC Power Source 320 Vrms, 6 KVA, 550 Hz
AC6906L
Keysight’s AC6900 Series three-phase power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument.
-
product
Primary Injection Testers
AT-10B
ETI’s AT-10B autotransformer steps-down 480V outputs to 240V outputs. This portable autotransformer allows ETI’s PI-1600 or PI-800 circuit breaker testers to be used at full-capacity on 240 and 480 VAC lines. The unit provides 240 VAC at 10 kVA, is housed in a rugged ABS enclosure approximately 22″ x 11″ x 22″, and weighs less than 125 lbs.
-
product
Multifunction Meters
Measures V, A, PF, Hz, KW, KVA, KVAr, Kwh, KVAh & KVArhTRMS MeasurementCan be used for Continuous MonitoringAuto / Manual Scroll Display (User Selectable)State of Art Microcontroller DesignPortable, Handy, Plug-n-Play and Easy-to-useLCD Display with BacklightRS-485 5KV Isolated Port (Optional) with MODBUS RTU Protocol (Optional)POWER MASTER Software for MIS Reports (Optional)
-
product
AC Hipots for Factory and Field Testing
HPA Series
HPA Series test sets perform AC withstand and PD testing (most models) on higher capacitance loads, offering up to 40 kVA and 300 kV AC
-
product
Programmable AC and DC Power Source
AFX Series
The AFX Series is a family of high power, single, split and three phase, AC, DC and AC+DC output capable Power Sources. Available models range from 6 kVA to 90 kVA with available configurations to 150kVA. Using a modern user interface for ease of use, the AFX Series is cost effective and fully programmable for both basic frequency conversion and advanced AC power line or DC power disturbance test applications.
-
product
Portable Circuit Breaker Tester
PI-1600
The PI-1600 Circuit Breaker Tester incorporates modular design and flexibility to provide unequaled capability in a portable package. The PI-1600 test set is two testers in one, incorporating the PI-800 and PI-AUX. The PI-800 section can be used alone, on 120 or 240 VAC supplies, generating continuous current of 400, 800, amps at 4.2 kVA, with peak output to over 10x. When configured for the PI-1600, the PI-AUX output unit is connected in series or parallel to the PI-800. The PI-AUX boosts total power to 9.8KVA, and allows testing of draw-out breakers and MCB’s to 1600 Amps. The units are housed in rugged interlocking suitcase-size enclosures. Each piece weighs no more than 125 pounds, allowing one-person hand truck mobility. Basic operation is very simple, and the proven MAC-21 control instrumentation provides optimal output control and measurement. The MAC-21 instrumentation is supplied in a separate rugged portable case, interlocks on top of the PI-800, and connects to a cable in the rear of the test set.
-
product
Burn Down Transformer
ATG 6000
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level
-
product
Regenerative AC Emulator, 600 VAC, 63 A, 45 KVA, 3‑Phase
SL1202A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Scienlab Dual-Range Regenerative AC / Grid Emulator, 600 / 1200 VAC, 63 / 32.5 A, 45 KW / 66 KVA
SL1214A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Multi-output AC Power Supplies (CV/CF)
PCR-LE2 Series
The PCR-LE2 Series are designed based on the PCR-LE Series that supports single-phase output, single-phase 3-wire output, and three-phase output within the rated capacity by selecting the switch from the front panel operation.The PCR-LE2 series offer the same basic performance, using the common power unit of the PCR-LE Series, with providing easier installation and saving the space more efficiently compare to the individual allocation of the system for a single phase, single-phase 3-wire, and three phase systems. The lineup of PCR-LE2 Series are available in 5 models:6 kVA, 9 kVA, 12kVA, 18kVA, and 27 kVA model.
-
product
Regenerative AC Emulator, 1200 VAC, 32 A, 45 KVA, 3‑Phase
SL1212A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Regenerative AC Emulator, 600 VAC, 125 A, 90 KVA, 3‑Phase
SL1203A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Bidirectional AC Source / Sink With Regenerative Power Supply
EAC-4Q-KS
*Single system from 15 kVA to 90 kVA and in parallel up to 500 kVA*Seamless transition between source and sink mode*Output: AC, DC, AC + DC*Output up to 2000 Hz (-HF option)*Add single-phase output (option -1P)*Up to 750 V LN output*Modular construction
-
product
Power Stabilizers
Manufacturer of a wide range of products which include 100 KVA Power Stabilizer, Three Phase Power Stabilizer, Electric Power Stabilizer, Industrial Portable Stabilizer, 50 KVA Power Stabilizer and 100 Kva Power Stabilizer.
-
product
Frequency Converter
Our frequency converters, which we offer with outputs of up to 500 kVA, can be used to supply alternating current consumers with constant voltages that deviate from the input network.
-
product
Three-Phase AC Power Source 320 Vrms, 12 KVA, 5000 Hz
AC6912H
Keysight’s AC6900 Series three-phase power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument.
-
product
AC Hipots for Apparatus Testing
PFT Series
PFT Series test sets are portable, ideal for testing substation apparatus. These are among the smallest, lightest, and most economical AC hipots available. Standard models are available from 10 kV AC – 100 kV AC and rated 1 kVA – 3 kVA.
-
product
Three-Phase AC Power Source 320 Vrms, 12 KVA, 550 Hz
AC6912L
Keysight’s AC6900 Series three-phase power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument.
-
product
Regenerative AC Emulator, 1200 VAC, 65 A, 90 KVA, 3‑Phase
SL1213A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
High Voltage AC/DC Testing Kits (Hipot Kits)
HV Testing Kits are used for testing of Motors, Generators, Switchgears, Cables, Transformers and other electrical equipment. These are used for testing & commissioning of HV electrical equipment. High Voltage AC Testing Kits are available in ratings from 25KV to 300KV AC in various mA and KVA Ratings.
-
product
HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY
xPS Series
High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)
-
product
Distribution Transformer Tester
ADOC-3
The ADOC-3 is an equipment that has been designed to test distribution network transformers from 5 kVA to 3MVA.
-
product
AC Clamp Meters
Power measure of Active power (KW), Reactive power (KVAR),Apparent power (KVA), Power Factor (PF)PF (cosØ), for 3Ø4W, 3Ø3W, 1Ø2W, 1Ø3W.Triple display: KW+V+A easy to read.Recorded each wire parameters of V, A, KW, KVA, KVAR, PF, Hz,total 25 parameters.AC current up to 1000A, AC voltage up to 600V.INRUSH (100mS), HOLD and PEAK functions.MAX and MIN recorded functions.MAX. Cable size: Ø34mm.Auto power off (10 mins), Black-light.EN61010-1, 600V CAT IV, 1000V CAT III.Dimensions: 246mm (H) x 80mm (W) x 43mm(D).
-
product
AC to AC Power Supplies, Output 0 to 25 VAC, 3000 AMPS, 75 KW, P/N 5955C
- AC to AC Power Supply, 84 KVA, 1 PH, 60 Hz, P/N 5955C- Input: 240 VAC, 350 Amps- Output: 0 to 25 VAC, 3000 Amps max- Back to back SCR is used to adjust the output voltage- Start / Stop push button- Power ON Light- Voltmeter and Ammeter are included to monitor output voltage and current- Indoor enclosure: 42″H x 32″W x 22″D- Estimated weight: (TBD)
-
product
Scienlab Regenerative 3‑Phase AC Emulator
SL1200A Series
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
Three-Phase AC Power Source 320 Vrms, 3 KVA, 5000 Hz
AC6903H
Keysight’s AC6900 Series three-phase power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument.
-
product
Scienlab Dual-Range Regenerative AC / Grid Emulator, 600 / 1200 VAC, 63 / 32.5 A, 90 KW / 135 KVA
SL1215A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
product
AC Voltage Testers
ALT Series test sets are designed for testing aerial lift devices (bucket trucks) but can also serve as portable, versatile all-purpose AC testers with an output of 0-60/120 kV AC @ 7 kVA, ideal for field, plant, and substation testing.
-
product
Aerial Lift Testers
ALT Series
HVI produces AC voltage testers that perform boom and liner testing, with models available up to 300 kV AC for boom testing and 10 kVA for liner testing. The ALT Series is designed for AC voltage testing aerial lift devices. The standard models available are rated 120/60 kV AC, 200 kV AC, and 300 kV AC, rated up to 7 kVA.