Filter Results By:
Products
Applications
Manufacturers
-
product
BACnet / Modbus
BACnet™ MS/TP and Modbus RTU communicating sensors provide an easy-to-install and cost-effective means to measure temperature and humidity anywhere on your network. They’re especially effective where there is limited controller inputs or the application is for monitoring only. All BACnet™ sensors are BTL Certified.
-
product
Residual Current Protection
Solutions to ensure the safety of people and installations against any ground currents. Available with ultra-immunized system as an essential solution to avoid financial losses due to outages caused by inadvertent trips. Specially designed to protect industrial installations in AC networks (type A), installations with both AC and DC components and DC-only installations (type B). Available with RS-485 communications (Modbus RTU) and remote control inputs/outputs.
-
product
Modbus to Profibus Converter
P485
The P485 Modbus to Profibus Converter acts as a gateway between a Modbus RTU network and a Profibus-DP network. Integration of Modbus devices into Profibus networks is enabled without loss of functionality, control, and reliability, both when retrofitting to existing equipment as well as when setting up new installations. The P485 Modbus to Profibus Converter is an external DIN-rail mounted device which provides Profibus network connectivity to Modbus devices via a serial RS232/RS422/RS485 interface.
-
product
RS232 RS485 RS422 Serial To Ethernet Modbus Converters / Device Servers
In the past two decades, legacy serial communication protocols such as Modbus have merged rapidly with modern TCP/IP communication, yielding benefits including widely available infrastructures and greater distance, reliability, and flexibility. CommFront offers a range of industry-proven, easy-to-use serial to Ethernet converters and device servers, both hardware and software types. The applications of our serial to Ethernet converters include acting as a device server or a Modbus RTU/ASCII to Modbus TCP protocol converter; extending serial ( RS232 / RS485 / RS422 / TTL) communication distance over Ethernet network; controlling serial devices from remote Modbus TCP software or Modbus RTU master via Ethernet network; making a wide variety of M2M communication applications possible by enabling client access independent of any operating system or proprietary protocol; and converting conventional serial data network into TCP/IP network, etc.
-
product
Magnetostrictive Level Transmitter
DM231
The Drexelbrook DM231 is an explosion proof liquid level transmitter offering high accuracy measurements based on the magnetostrictive sensing technology.The DM231 comes with a Modbus RTU digital output (optional analog output converter available) for total level, interface level and temperature sensor outputs. Sensors are available in 316SS rigid designs with a choice of single or dual NPT mountings. Temperature sensors are evenly distributed over the active length of the rigid 316SS tube.Due to a wide selection of floats and mounting accessories this level transmitter fits virtually any application.The DM231 level transmitter is FM approved for Class 1 Div. 1, Zone 1 Explosion Proof hazardous area installations. It is easy to install and requires no calibration.
-
product
Multifunctional Meter
CPM-10
Chuan Sheng Electronics Co., Ltd.
CPM-10 Multifunction Power meter measure single phase 2 wire ,single phase 3 wire, three phase 3 Wire and 3 Phase 4 wire systems with high accuracy measurement for parameters such as voltage, current ,active power, reactive power, apparent power, power factor ,frequency, effective energy (V,A,W,Watt-Hr,Var,Var-Hr,VA,PF,Hz), having LED display and standard communication RTU Modbus RS485..Optional functions 1 set relay output,1 analogue,1 RS485 (ModbusRTU Mode) or 1 pulse output. Most suitable for power management,remote input /output, alarm and remote signal control uses needs.Case depth 120mm only, easy panel mounting installation
-
product
5 Digit Frequency Meter
CS1-F
Chuan Sheng Electronics Co., Ltd.
CS1-F economic type Frequency Meter is designed with high accuracy measurement, display and communication of Frequency.The innovation feature is auto-range input from 0.01Hz~100KHz(option ~140KHz) and the display resolution will auto-change to show the highest according to input frequency.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of panels and testing applications.
-
product
4 Digit Process Meter
CM2-PR
Chuan Sheng Electronics Co., Ltd.
CM2-PR Process Meter has been designed in simple operation and 4 digital 20mm LED display with economic cost.They are can be programmed by buttons that are hidden in front panel.They are also available to option 2 relay output and an analog output or RS485(Modbus RTU Mode) communication.
-
product
Multifunction Meters
Measures V, A, PF, Hz, KW, KVA, KVAr, Kwh, KVAh & KVArhTRMS MeasurementCan be used for Continuous MonitoringAuto / Manual Scroll Display (User Selectable)State of Art Microcontroller DesignPortable, Handy, Plug-n-Play and Easy-to-useLCD Display with BacklightRS-485 5KV Isolated Port (Optional) with MODBUS RTU Protocol (Optional)POWER MASTER Software for MIS Reports (Optional)
-
product
Modbus to DeviceNet Converter
D485
The D485 Modbus to DeviceNet Converter acts as a gateway between a Modbus RTU network and a DeviceNet network. Integration of Modbus devices into DeviceNet networks is enabled without loss of functionality, control, and reliability, both when retrofitting to existing equipment as well as when setting up new installations.
-
product
Total Tank Level System
The Total Tank Level System is an intrinsically safe and explosion proof level sensor with several communication options. Outputs include Modbus RTU digital, dual 4-20mA and HART. The Modbus version is offered in a single housing and the 4-20mA and HART output product features a dual compartment housing and display.
-
product
Economic Type Resistance Indicator
CS1-RS
Chuan Sheng Electronics Co., Ltd.
CS1-RS economic type Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm(2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.
-
product
Economic Type Strain Gauge/Load Cell Indicator
CS1-SG
Chuan Sheng Electronics Co., Ltd.
CS1-SG economic type strain gauge/load cell indicator is equipped with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV.It supports field calibration, and It can calibrate with sensor (load cell/strain gauge) according to actual needs.It is able to select one from these three functions, 1 relay output, 1 analogue output or 1 RS-485 (Modbus RTU Mode) interface; they provides many functions such as control, alarm, re-transmission, and communication.
-
product
Thermocouple Temperature Indicator
CM2-TC
Chuan Sheng Electronics Co., Ltd.
CM2-TC Thermocouple Temperature Indicator has been designed in simple operation and 4 digital 20mm LED display with economic cost.They are can be programmed by buttons that are hidden in front panel.They are also available to option relay output and an analog output or RS485(Modbus RTU Mode) communication.
-
product
10 Digit Rate/Batch Counter (Analogue)
CS2-TM-Analogue
Chuan Sheng Electronics Co., Ltd.
The CS2-TM Totalizer controller provide high accuracy measurement, display, control and communication (Modbus RTU mode) of 0~10V/4~20mA from flow meter or mV from Shunt for Amp-Hour.There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also support fantastic control function as like as N, R, C mode for totalizer and batch control.
-
product
4AO/4DI Modbus RTU Remote I/O
ND-6124
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
product
4 Digit Voltage/Current Meter
CM2-VA
Chuan Sheng Electronics Co., Ltd.
CM2-VA Voltage/Current Meter is designed in simple operation and 20.0mm LED displays in 4 digits with economic cost.They are can be programmed by buttons that are hidden in front panel.They are also available to option relay output and an analog output or RS485(Modbus RTU Mode) communication
-
product
Networked Absolute Inclinometer
T7
The T7 is available in several interface and protocol options. The physical interface can be RS232, RS485 or US Digital's CAN (Controller Area Network). The protocol can be either US Digital's serial protocol or Modbus RTU. The RS232 version supports a single T7 with up to 100 ft of cable. For users that need longer cable lengths or multiple T7s on a single bus, the RS485 or US Digital CAN (Controller Area Network) version can be used. The USD-CAN protocol allows a network of up to sixty-four T7s to be connected to a single host. Power for each T7 is supplied over the CAN network cable. The host accesses the USD-CAN T7s through US Digital's low cost CANA-232/CANA-485 adapter module. This module allows the host to access each T7 on the network using simple, easy serial port commands, just like the RS232 version. The RS485 version supports up to 32 T7s on the bus.
-
product
Universal Transmitter
Model LXT-380
Teledyne Analytical Instruments
The Model LXT380 transmitter is a single or dual channel, intelligent, multi-parameter designed for the online continuous measurement of pH, ORP, Specific Ion (pION), dissolved oxygen, free chlorine, total chlorine, conductivity and resistivity. The Model LXT380 Tramsitter digitally communicates with the SP3X digital sensor, automatically configuring the trasmitter's menues and display screens to the measured parameter. The LXT380 tramsitter can be Loop powered or 4-wired DC powered. The standard configuration has a 4-20 mA and a serial communication port with MODBUS RTU output. Alarm relays option is only available on 4-wired DC powered transmitters. LXT380 Transmitter loop is available in FM, ATEX and IECEx certifications.
-
product
Modbus RTU Analog Input
Provide direct connection to a wide variety of sensors to any host with an RS232 or RS485 port. The modules perform all signal conditioning, scaling, linearization, and A/D conversion. They each contain some discrete digital I/O lines and can measure signals such as:
-
product
Modbus RTU Analog Input Modules
The Datexel range of Modbus RTU analog input cards for both RS485 and RS232 with Modbus or ASCII protocol can be combined with the DAT9000 series of Modbus Masters. A choice of input cards or modules are available and have various optional inputs such as Voltage, Current, Thermocouples, RTD, and Resistance. Also a choice of 2, 4, 8 channel options are available. The DAT3011 is a Modbus RTU Slave with 1 selectable universal input (Thermocouples, RTD, mV, RTD's or Resistance), 2 x 4-20mA or 0-10V input and 2 x4-20mA outputs. The DAT3011 also has 3 digital inputs and 3 relay outputs. Each module is isolated from each other and is set up using the DAT3000 software Development package which is free of charge from the Datexel download web page. Datexel also has universal input modules. An 8 channel analog input card is available making the DAT3000 series a very economical solution to large and small scale Data Acquisition. Combining these analog input cards with the analog output cards, the digital input/output cards and the communication devices make Datexel the smart choice where Data Acquisition is required.
-
product
4 2/3 Strain Gage Meter
CS2-SG
Chuan Sheng Electronics Co., Ltd.
CS2-SG Strain Gauge Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV as like as Load Cell or Strain Gauge.The meter supports Field Calibration function. It can be calibrated with sensor(Load Cell/Strain Gauge) to meet machinery structure.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS-485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.
-
product
Digital Ethernet Power Meters
FU2200A
Beijing GFUVE Electronics Co.,Ltd.
Digital Ethernet power meter with data logger is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems. It may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a standard digital RS485 communication port, which is based on the Modbus RTU protocol.
-
product
Oxygen Analyzer
DT3000
The Datatest Model DT3000 is a Zirconia sensor, microprocessor based, oxygen analyzer. The DT3000 comes with probe configurations for temperatures up to 3200F. The microprocessor based controller provides long-term stability and reliability, plus optional features for controlling back purge, calibration gas injection, and self-calibration. 4 - 20 mA output and Modbus RTU serial port are standard. The DT3000 is available in either a NEMA 4 wall mount or panel mount configuration.
-
product
Modbus PLC Simulator
This protocol simulator started one weekend as a test program while developing a SCADA/HMI with modbus RTU and TCP/IP and afterward came in useful testing an embedded gnu-Linux device too. It has worked so well for me, I decided to put a nice GUI onto it and release it for free. The modbus protocol, also called open-mbus is implemented in many process control and monitoring devices, while most SCADA or HMI systems have a driver.
-
product
Self-reclosing Overcurrent And Residual Current Protection
Wide range of solutions to guarantee personnel safety as well as maximum service continuity in the event of a ground current or breaker trip, with automatic reconnection of the installation. Available with RS-485 communications (Modbus RTU) and remote control inputs/outputs.
-
product
RS485 Remote Display Indicator
CS1-8
Chuan Sheng Electronics Co., Ltd.
CS1-8 has been designed for remote display by RS485 (Modbus RTU Mode) interface.
-
product
Load Cell Transmitter
MODEL SST-HV
The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.
-
product
Load Cell Transmitter
MODEL SST-LV
The SST-LV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-LV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-LV may be powered from 12-30 Vac or 10-48 Vdc. The SST-HV Has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.
-
product
Signal Conditioners & Interface
Modbus RTU Remote Connectivity and Control. Minimize Long Cable Runs with Modbus Network. Pulse to Frequency Conversion. Shaft Speed Pulse to DeviceNet. Shaft Speed Pulse to 4-20 mA Conversion.Sensor Compatibility