product
Modular Breakout System 37-Pin Plugin Module
95-294-001
The 95-294-001 Plugin Breakout Module is designed to be fitted to a PXI 40-294 Programmable Resistor Module as part of the Pickering MBoS. The Modular Breakout System is designed to Simplify HILS (Hardware In the Loop Simulation) Applications.
-
product
Power Sensors
RTP5540
Providing the highest video bandwidth and fastest rise times, the 50 MHz to 40 GHz Power Sensor by Boonton is the ideal instrument for fast, accurate and reliable RF power measurements. This module is ideal for many different applications including Crest Factor and Peak to Average Power Ratio (PAPR) measurements for Power Amplifiers and RF components; Telecommunication & Satellite signals: W-CDMA, QAM, OFDM, LTE-FDD and LTE-TDD; WiFi signals: 802.11ac and legacy 802.11 a/g/n/b; RF and Microwave pulse modulated power measurements: RADAR, MRI, Particle Accelerators; General purpose scalar measurements such as gain and return loss using modulated and pulsed signals as well as CW; and Monitoring, Recording, ALC loops, transient phenomena.
-
product
sbRIO-9265, Non-Enclosed, 4-Channel C Series Current Output Module
780921-01
Non-Enclosed, 4-Channel C Series Current Output Module - The sbRIO‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The sbRIO‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.
-
product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
product
Optical Rotary Encoders
Optical sensing technology is the most precise and offers the highest resolution of the position sensing technologies. Rugged construction and years of field proven service makes BEI optical rotary encoders ideal for operating in harsh industrial environments including oil well drilling, machine control, agricultural machinery, web process control, robotics, elevators, construction equipment, cranes, motor feedback and any closed loop control systems. BEI optical encoders are available as incremental, absolute single-turn, and absolute multi-turn. BEI Sensors programmable encoders offer resolution flexibility to match changing needs while also saving on inventory costs and reducing machine downtime.
-
product
PXIe-2725, 8-Bit, 18-Channel PXI Programmable Resistor Module
781986-25
8-Bit, 18-Channel PXI Programmable Resistor Module - The PXIe‑2725 is a test module that replicates the behavior of resistance-based inputs and outputs such as potentiometers, resistance temperature detectors (RTDs), voltage dividers, and bridge elements. The PXIe‑2725 programmatically controls a series of relays to vary the resistance across each channel of an I/O connector. This function is well suited for simulating environmental conditions in hardware‑in‑the‑loop (HIL) validation. The software provides a simple user interface that accepts inputs in units of temperature or resistance and configures the resistance across each channel.
-
product
terraTEM Receiver Coils
TRC
The terraTEM multi-turn receiver coils (TRC) are designed to be used in place of largTRC ver sideviewXe receiver loops, placed either inside or outside the transmitter loop with the measurement point being at the location of the TRC. The compact size of the TRC receiver, measuring just 0.6m x 0.6m x 0.33m, makes the multi-turn coils convenient to use, and is available in either single component or three component form with the latter requiring the multi-channel receiver option to be fitted to the terraTEM.
-
product
80W - Single Output
iBH Series
*DOSA Compatible Footprint*3.5-14 Vdc Input*0.7-5.5 Vdc Output*Non-Isolated*Excellent Transient Response*No external loop tuning components needed
-
product
Signal Generator Adapter Module For FlexRIO
Signal Generator Adapter Modules for FlexRIO feature either high or low‐speed analog output and can be paired with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO for custom signal generation. Whether you need to dynamically generate waveforms on the FPGA or stream them across the PXI backplane, these adapter modules are well suited for applications in communications, hardware‐in‐the‐loop (HIL) test, and scientific instrumentation.
-
product
Fast Temperature Shift
CherryTemp
CherryTemp is a temperature controller based on two independent Peltier channels, allowing for very accurate temperature control and ultra-fast shifts from 5°C to 45°C. A thermalization liquid circulates from a reservoir to the heat exchangers (heating/cooling Peltier elements) where it is thermalized to a target temperature. Once thermalized, this liquid can be quickly injected to a microfluidic device (CherryTemp chip) mounted near the sample. Because of the small thermal mass (the distance between the microfluidic chip and the sample), the temperature transfer is very fast (less than 10 seconds) and of unprecedented accuracy due to a feedback loop control of the room temperature and the heat-sink played by immersion objective lenses.
-
product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
product
150W - Single Output
iAH Series
*DOSA Compatible Footprint*3.5-17 Vdc Input*0.7-5.5 Vdc Output*Non-Isolated*Excellent Transient Response*No external loop tuning components needed
-
product
3U OpenVPX SOSA™-aligned PWM Servo Motor Drive
68PW1
The 68PW1 is a 3U OpenVPX SOSA™-aligned (basis, Snapshot 2) single-axis PWM servo motor drive that can be configured with closed loop feedback measurement options including Hall, Resolver/Synchro or Encoder. The PWM drive provides programmable PWM output drive (up to 65 V @ 10 A continuous) from a single +28 VDC input source. Ideally suited for rugged Mil-Aero applications, the 68PW1 delivers off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
product
PXIe-7846, Kintex-7 160T FPGA, 500 kS/s PXI Multifunction Reconfigurable I/O Module
784143-01
Kintex-7 160T FPGA, 500 kS/s PXI Multifunction Reconfigurable I/O Module—The PXIe‑7846 features a user-programmable FPGA for high-performance onboard processing and direct control over I/O signals to ensure complete flexibility of system timing and synchronization. You can customize these devices with the LabVIEW FPGA Module to develop applications requiring precise timing and control such as hardware‑in‑the‑loop testing, custom protocol communication, sensor simulation, and high-speed control. The PXIe‑7846 features a dedicated A/D converter (ADC) per channel for independent timing and triggering. This design offers specialized functionality such as multirate sampling and individual channel triggering, which are outside the capabilities of typical data acquisition hardware. The PXIe‑7846 also includes peer-to-peer streaming for direct data transfer to other PXI Express modules.
-
product
RS-232 to RS-422 Optically Isolated Interface Converter
Model 265
FEATURES: Eliminates Ground Loops; 19.2 KBPS at 2 Miles;TD and RD Indicators; Use in Pairs as Double Isolated Short Haul Modems; Use in Pairs as Double Isolated Short Haul Modem. Total isolation between RS-232 based systems and RS-422. Unique circuitry allows the RS-422 port to withstand surges exceeding 10 kilovolts.
-
product
Magnet Tester
H30 Series
AlmiCo, Ferrite, NdFeB, SmCo5, Sm2Co17 magnets are tested and their B-H and MH loops are plotted using Ferrites India make H30 Series hysteresis loop tracers. The complete system consists of a magnetizer to magnetize the test piece, an electromagnet and a BH Loop Plotter. Magnets with coersivity as high as 13 kOe and more can also be tested.
-
product
PCI-8513, 2-Port, Software‑Selectable/FD CAN Interface Device
780684-02
2-Port, Software‑Selectable/FD CAN Interface Device—The PCI‑8513 is a controller area network (CAN) flexible data-rate (FD) interface for developing applications with the NI‑XNET driver. NI‑XNET software-selectable CAN interfaces offer the best flexibility for CAN development with onboard transceivers for high-speed/FD, low-speed/fault-tolerant, and single-wire CAN as well as any external transceiver. The PCI‑8513 excels in applications requiring real‑time, high‑speed manipulation of hundreds of CAN frames and signals such as hardware‑in‑the‑loop simulation, rapid control prototyping, automation control, and more. The NI‑XNET device‑driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts.
-
product
500 HP Complete Bench Hydraulic Test Center With High Flow Supply
HTC-500-HFS
The Hydraulic Test Center (HTC) is a versatile machine designed to test heavy-duty, off-highway hydraulic components. The 500 hp (373 kW) HTC Complete Bench is for the dealer that services components from a predominately larger machine size mix such as large mining machines and large excavators. The Complete Bench offers full functionality to test all types of pumps and motors including: transmissions, hydraulic motors, hydraulic cylinders, valve blocks, torque converters, open and closed loop pumps.
-
product
32Ch Isolated Input Card
SET-1310
This card provides 32 optically isolated digital inputs. SET-1310 combines high-density IO with high isolation voltages and a wide input voltage range. It allows to break ground loops and protect your system from high-voltage spikes, but also to connect high voltage signals to standard logic level acquisition devices. The channel-to-channel isolation allows to connect signals from different DUTs to a single acquisition system without compromises.
-
product
Elite™ 13.56 MHz RF Plasma Generators
The elite™ Series of RF plasma generators provides state-of-the art technology in a compact air-cooled package. The elite is designed with high speed closed loop control, a class E RF deck and a switching modulator for superior output performance. The elite design utilizes a single printed circuit board assembly for the full rack product virtually eliminating all internal wires and connectors and thereby providing the highest reliability available.
-
product
85W - Single Output
iCH Series
*DOSA Compatible Footprint*4.5-14 Vdc Input*0.7-8.5 Vdc Output*Non-Isolated*Excellent Transient Response*No external loop tuning components needed
-
product
Insolator
The USB isolators effect a potential decoupling of all USB connections and separate the 'normal' PC system from the critical application. They are the professional tools to avoid and fight ground loops and equalizing currents and to protect against overvoltage.
-
product
Quality Assurance
Functional Test Code Coverage
Applications are developed with multiple builds each containing unique incremental code changes. In today’s reality of incremental code changes, especially functional, API and regression testing, CI/CD pipelines need simple Functional Test Code Coverage to enable visibility and quick feedback loops.
-
product
15GHz Frequency Synthesizer
5015
The Valon 5015 frequency synthesizer uses multiple phase lock loops to provide exceptionally low phase noise over the 10MHz to 15GHz range. The multiple loop technique also greatly reduced spurs while providing high resolution tuning precision. Calibrated output power may be accurately set from +13dBm down to -30dBm in 0.1dB steps.
-
product
H/L Voltage Clamp Meters
High Voltage Current Transformation Ratio Tester breaks traditional structure, specially designed for high and low voltage first and secondary loop current, variable ratio, and current leakage test; apply the latest CT technology and mask digital integration technology, composed of special high-voltage clamp, low voltage clamp, host, high voltage insulation rod and monitoring software, etc; its wireless transmission test data can penetrate multiple building obstacles with a straight-line distance of 30 meters.
-
product
LXI High Density 16x64 2A Matrix with BIRST
60-552-021
It is constructed from 8x64 sub-assemblies, permitting the matrix to be supplied in a variety of sizes from a single 16 x 64 to 64 X 64 and dual 8x64 to 32x64. Larger configurations can be easily achieved by utilizing the Loop thru connections on either the X or Y bus, for instance, four 64x64 units can be linked to create a 128x128 matrix.
-
product
Loopworks Measure iOS App
Loopworks is a unique suite of online and App-based tools and resources designed by Ampetronic to enable its customers to understand, specify and design Hearing Loop systems.
-
product
USB-7846, Kintex-7 160T FPGA, 500 kS/s Multifunction Reconfigurable I/O Device
783201-01
Kintex-7 160T FPGA, 500 kS/s Multifunction Reconfigurable I/O Device - The USB‑7846 features a user-programmable FPGA for high-performance onboard processing and direct control over I/O signals for complete flexibility of system timing and synchronization. You can customize these devices with the LabVIEW FPGA Module to develop applications requiring precise timing and control such as hardware‑in‑the‑loop testing, custom protocol communication, sensor simulation, and high-speed control. The USB‑7846 features a dedicated A/D converter per channel for independent timing and triggering. This design offers specialized functionality such as multirate sampling and individual channel triggering, which are outside the capabilities of typical DAQ hardware.
-
product
RS-232 and RS-562 Transceivers
Analog Devices offers single, dual, and combination transceivers of up to five RS-232/RS-562 drivers and receivers for 1.8 V to 5.5 V power supplies. Data terminal equipment (DTE) or data communications equipment (DCE) configurations are also available in 3.3 V or 5 V versions. Galvanically isolated modules break ground loops and provide a convenient, self-powered, isolated, low EMI solution that drastically reduces component count and design complexity.
-
product
Temperature Transmitter
T4111
Transducer is designed for temperature measurement at C or F by means of an externaltemperature probe with Pt1000 sensor. Measured temperature is converted to linearized unified signal 4-20 mA. Measured values are displayed on LCD display. It is possible to switch OFF theLCD at all. Current loop has two-wire connection and requires power from evaluation device.