Load Banks
Test a power source by providing controlled amounts of load to create conditions found in thier application.
See Also: AC Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks, Resistive Load Banks
- Pickering Interfaces Inc.
product
PXI 8 Bank 8 Channel 2 Pole Multiplexer
40-659-102
Model 40-659 is an 8 Bank 8 Channel Multiplexer module with 2-pole switching, It uses high quality electromechanical relays and is suitable for switching signals up to 2Amp, 300VDC/250VAC.The 40-659 module is suitable for multiplexer applications where two signals are required to be switched simultaneously, for example send and return signals in a telecoms system. It is also suitable for applications where reed relay based multiplexers do not have sufficient power handling capability such as switching medium power AC or DC loads or for slaving external relays, contactors and solenoids.
-
product
Inductive Load Banks
L-Series
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
product
Load Bank
RLB
RARA manufactures load banks, ranging from small portable units for testing generators to multi-megawatt designs for larger applications. Regular load testing, along with correct battery maintenance, is the best way of ensuring the reliability of standby power systems. It is routine for all newly-installed generating sets to have a load test during the commissioning process in order to prove the performance of the set and all ancillaries-cooling system, exhaust system, switchgear and protection schemes.
-
product
AC Load Bank (Rack Mounted)
K-1000 Rack Mounted
Kongter Test & Measurement Co., Limited
Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.
-
product
Battery Capacity Tester
BLU-T Series
Battery load bank BLU-T is a powerful and lightweight solution designed for condition assessment of telecommunication and radio equipment backup supply. This instrument can perform the battery capacity test on battery strings such as Pb, Li-ion, Ni-Cd, and others. It tests battery strings with voltages in the range of 0,9 – 70,5 V DC. As a special feature, the BLU110T model enables capacity testing of single PB, Ni-based as well as Li cells (with current up to 100 A).The capacity test is conducted in an accurate, user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU-T battery load bank enables setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, the BLU-T units can be connected in parallel, or BXL-T additional load units can be linked.The instrument offers a high power-to-weight ratio. BLU-T series has models starting from 12,8 kg / 28.2 lbs and up to 19,2 kW of power.A user can select one of three discharge modes: Constant current, Constant power, Constant resistance. Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.Discharge parameters can be monitored in real-time during the capacity test. A 4,3-inch touch screen shows overall battery voltage, discharge current, discharge test time and capacity during the entire test. Also, the capacity tester is compatible with DV-B Win software. A user can view a detailed numerical and graphical presentation of key parameters, and create reports in various formats.Testing can be carried out without disconnecting the battery from the service.
-
product
Load Banks
Power House Manufacturing, Inc.
Load banks manufactured by Power House are engineered to be smaller and lighter than the competition.
-
product
AC Load Bank (Resistive/Reactive)
K-1000 Resistive/Reactive
Kongter Test & Measurement Co., Limited
Resistive/reactive load banks are great choices for testing turbines, switchgear, rotary UPS, generators and UPS systems. They can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others. A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage.
-
product
Battery Test & Management
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of products for testing and measurement of battery from your critical power systems. It includes battery online monitoring system, battery tester for internal resistance/conductance, battery charger, battery load bank, battery data logger, battery charger/discharger and so on.
-
product
Load Banks
EL Series
*12kW, 15kW and 18kW DC Electronic Load*All of our Load Banks are continuously rated for Power and Current.
-
product
Load Banks
PT04 Series
Quality ProductRugged and Reliable DesignCurrent control from 0 to 70A on 64V RangeCurrent control from 0 to 135A on 32V Range4kW plus rating (at 40°C ambient)Cost effective; simple robust designCC, CP, CR and CV modes as standardCurrent control from either ATE with0 – 5V demand input or from a RemoteControl Box (both standard)Ultra Low electrical noiseSelectable Range 64V or 32VTemperature controlled quiet fans19 Inch Rack case 4U
-
product
Variable Resistor Load Bank
REOLOAD 100
A variable resistor load-bank with fixed stages connected in parallel and switched in, as required, with an adjustable stage for fine trimming. Designed for testing equipment under load. 1000V (AC or DC). 250A and 2500
-
product
Battery Testing System
C8000
The Cadex C8000 stands in a class by itself in flexibility and affordable price. Test SMBus batteries, monitor cell balance and capture load signatures to observe batteries with a unique load protocol. Add a thermal chamber, an external load bank, a safety circuit and alarm to form a command center and you begin realizing the unique qualities of this fine battery testing system.
-
product
PXI Single 18 Channel MUX, BNC Connectors
40-735-902-S3
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
Rack Mounted Load Banks
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.
-
product
Outdoor Permanent Mounted Load Bank
Mosebach Manufacturing Company
Mosebach Pad Mounted Load bank is designed to be permanently mounted next to a generator for dedicated testing. Its unique design allows it to be one of the smallest on the market! This size enclosure will fit 50 kW, 75 kW or 100kW of testing ability. Also available in 300kW and larger load banks.
-
product
Load Banks
PARELO
Amfax introduce the latest generation of load banks we affectionately call PARELO. This range of load banks provides a combination of high performance passive resistive loads along with extreme flexibility of use. This is achieved by our unique FLEXI-phase Switching(TM) technology.. Designed primarily for offering high wattage loads for the aerospace, energy, automotive and transport sectors. PARELO load banks are a cost effective solution for companies requiring high wattage loads when testing their products.
-
product
Resistive & Capacitive, Inductive AC Load Bank
RLC
Inductive & capacitive load banks are reactive only and must be used in combination with a resistive load bank to provide the desired load profile to test a power system. Reactive loads banks can provide either a leading power factor (Capacitive) or lagging power factor (Inductive).
-
product
Uni-Therm High Current Electrosurgical Analyzer
A unique high power low inductance load bank enables performance testing up to 8 ampere RMS with a duty cycle of up to 100% making the analyzer an extremely versatile test instrument for calibrating and performance testing of conventional and high power electrosurgical generators. The load bank allows testing in a range of 0-5115 with a resolution of over 1000 steps providing high detailed power profiles. The Rigel Uni-Therm also advocates safe working practise by providing all necessary resistors within a single enclosure.
-
product
DC Resistive Load Banks
LB-Series
Eagle Eye offers multiple DC Load Banks ranging from 10 480 VDC at 1 amp or 5 amp Resolution. These load banks offer a simplistic solution to UPS Battery Load Testing. Each load bank is easy-to-use with an LCD display operator control panel and user-friendly fan switches, load step switches, and master load switches. UPS load testing stimulates a real-world performance demand of a critical power
-
product
Load Banks
EL08 Series
*Rectifier Test 8kW*All of our Load Banks are continuously rated for Power and Current.
-
product
AC & DC Loadbanks
Regular load bank testing of generators provides an essential health check service to prevent diesel engine failure due to wet stacking. Wet stacking occurs due to under loading of the genset which results in wet un-burned fuel building up in the engine. This fuel build up will over time line the combustion chamber cylinders and cause a reduction of the engines rating and efficiency which will ultimately cause premature failure of the generator. Running the generator on load of 50% - 100% of the genset rating will allow the engine to reach the recommend operating temperature, which will burn off the choke deposits.
-
product
AC Load Banks
XL2000-XL3000 Series
Mosebach Manufacturing Company
The XL2000-XL3000 Series is a group of outdoor rated load banks ranging from 2000 kW to 3000 kW. These load banks range in features from permanently mounted with direct bus bar connections to trailer mounted and easy disconnect cam lock connections. Mosebach can also integrate a wide variety of control systems into the load bank to meet your needs.
-
product
Load Banks
BD Series
*12 kW, 15kW and 18kW Battery Discharge Load DC*All of our Load Banks are continuously rated for Power and Current.
-
product
AC Load Banks
XL300-400 Series
Mosebach Manufacturing Company
The XL300-400 Series of Load Banks offer 300 kW or 400 kW in various voltages in a compact, lightweight enclosure.
-
product
Custom Load Banks
Power House Manufacturing, Inc.
Custom Load Banks are our specialty. Power House Manufacturing is dedicated to providing our customers with exactly what they need. Having years of custom load bank manufacturing experience, Power House can deliver the perfect custom testing solution you require.
-
product
Automatic Power Factor Controller
Power factor controlling based on the capacitor bank switching historyCapacitor is automatically disabled when it is deteriorated beyond a certain levelAutomatically learns the number of capacitors connected and the value.Capacitance-based power factor correction takes care of variation in voltage and frequency.Controlling based on VAR parameter and availability of built-in alarms Flexibility for site programmability of CT ratio suitable for any load
-
product
Radiator Mounted Load Banks
RD-Series
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
product
Multi-Unit Controllers
Mosebach Manufacturing Company
Mosebach’s Multi-Unit Controllers are built to help you manage your load banks in operation – whether 10, 20 or 500 units ganged together.
-
product
AC Load Bank (Resistive)
K-1000 Resisitive
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.
-
product
Radiator Mount Load Banks
Mosebach Manufacturing Company
Help prevent wet stacking in diesel gensets with a radiator or duct mounted load bank. Being a supplemental load, Mosebach has a solution to fit your needs.