Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Battery Simulator Module, 2-Channel, Simplified Current Sink, 750 V Isolation
43-752A-903
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
sbRIO-9265, Non-Enclosed, 4-Channel C Series Current Output Module
780921-01
Non-Enclosed, 4-Channel C Series Current Output Module - The sbRIO‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The sbRIO‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.
-
product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
product
Insolator
The USB isolators effect a potential decoupling of all USB connections and separate the 'normal' PC system from the critical application. They are the professional tools to avoid and fight ground loops and equalizing currents and to protect against overvoltage.
-
product
H/L Voltage Clamp Meters
High Voltage Current Transformation Ratio Tester breaks traditional structure, specially designed for high and low voltage first and secondary loop current, variable ratio, and current leakage test; apply the latest CT technology and mask digital integration technology, composed of special high-voltage clamp, low voltage clamp, host, high voltage insulation rod and monitoring software, etc; its wireless transmission test data can penetrate multiple building obstacles with a straight-line distance of 30 meters.
-
product
Temperature Transmitter
T4111
Transducer is designed for temperature measurement at C or F by means of an externaltemperature probe with Pt1000 sensor. Measured temperature is converted to linearized unified signal 4-20 mA. Measured values are displayed on LCD display. It is possible to switch OFF theLCD at all. Current loop has two-wire connection and requires power from evaluation device.
-
product
Battery Pack Test System
*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery.
-
product
Split Core Hall Effect DC Current Sensor
CYHCT-C2TC
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a split core and a high galvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
AC Current Sensor
RCTi and RCTi 3ph
The RCTi & RCTrms sensors convert ac current to an isolated 0-5V voltage or 4-20mA current loop. TA5V-5A allows compatibility with existing 1A or 5A CT metering circuits. Both offer a choice of proportional (rms) and instantaneous outputs. The available RCT current ranges are 0-100A to 0-50,000Apk. Both RCTi and RCTrms provide accurate measurement over a wide bandwidth ensuring precise measurement even with harmonically distorted wave shapes - using a flexible clip-on sensing coil. The RCTs are available as single and three phase models.
-
product
PXI Analog Output/Current Loop Simulator Module - 12 Channel
41-765-002
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Current Sense Amplifiers
Analog Devices’ current sense amplifiers offer excellent performance for a wide array of automotive and power management applications. These devices accurately amplify small voltages in the presence of large common-mode voltage, and provide high bandwidth, as well as level shifting and bidirectional capability. Excellent dc and ac accuracy over a wide temperature range from –40°C to +125°C minimizes errors in your measurement loop while not sacrificing on cost and package size.
-
product
Anti-Tamper Sub-Assemby (DC Immune CTs + Potential Transformer)
Shanghai Powoo Industry Develop Group Limited
ATS can provide double loop current sampling and power supply for measuring unit of static meter. When load voltage, static meter can in normal condition without single-channel current.
-
product
Current Loop Adapter
OP-1C
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
Lightning Current Generator
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.
-
product
Microwave Moisture Meter
RX-95
The system works based on the absorption of microwave energy by water molecules contained inthe x-rayed material. It is a non-contact, non-destructive method of instant measurement of water content - used for materials such as coal, flour, grain, cement, seeds, sugar, etc. Thanks to high measurement sensitivity (resolution greater than 0.01% of water content by weight), short measurement time (about 5 times/sec.) and repeatability of measurement - the system is suitable for continuous measurement of material moisture, e.g. on conveyor belts and its recording on a PC or using a 4-20 mA current loop.
-
product
Downloading Multifunction Tester
ET4500
The new ET4500 tester carries out all the tests needed to verify the safety of electrical installations in domestic, commercial and industrial wiring installations in accordance with the latest regulations.
can be used to carry out 3 wire earth testing and has on board memory to store and download all installation test results for documentation.
Everything about the new ET Series has been designed to save time and make testing easier.Fast, reliable high current and non-trip loop testing comes as standard together with a high level of input protection and a CAT IV safety rating .Supplied with a full range of accessories.
-
product
Multifunctional testers
MI 3152 EurotestXC
MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.
-
product
Signal Isolators & Converters
Devar current loop signal isolators reduce problems found in field measurements when signal transmitters or converters encounter both input and output signals that may be grounded. Current loop isolators eliminate these ground loops and are available as input loop powered or output loop powered instrumentation.
-
product
PXI Analog Output / Current Loop Simulators
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
product
Current Loop 20 MA Constant Current SI-module With Optical Isolation
MXTTY
Current loop 20 mA constant current (active, passive) SI-module with optical isolation.
-
product
PXI/PXIe Analog Output/Current Loop Simulator Module - 16 Channel
43-765-001
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Micro Ohmmeter
HTHL-200P / 384
Wuhan Huatian Electric Power Automation Co., Ltd.
High-precision measurement for high-voltage switch contact (loop) resistance, also suitable for other occasions requiring high current and micro resistance measurement.
-
product
Helmholtz Coils / Radiating Loops
Formed by a pair of conducting circular coils with many turns, each carrying a current. The coils are separated by a distance equal to the radius of the circular loops.
-
product
Current Loop Calibrator
LC-100
The Current Loop Calibrator an accuracy of 0.015% and a 0.001 mA resolution. The loop calibrator can simulate, power, and measure two-wire transmitters. With automatic Step and Ramp functions, the precision loop calibrator also enables remote calibration of 4-20mA devices.
-
product
NI-9265, 4-Channel C Series Current Output Module
779334-02
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
AC Power Sources, Frequency Converter
MAC-01, -02, -03
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
product
Open Loop Current Sensor
K03
The K03 series is a current sensor based on the Hall effect. It enables the electronic measurement of direct, alternating or pulsed currents as well as their combinations with galvanic separation between primary (high current) and secondary circuits.
-
product
Split Core Hall Effect DC Current Sensor
CYHCT-C2TV
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a split core and a high galvanic isolation between primary conductor and secondary circuit. It can be used for measurement of DCcurrent etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
Fibre Channel PXI Express Test & Simulation Instrument
PXIe-FC4
Avionics Interface Technologies
3U PXIe form factor will fit into any PXIe or hybrid slot - Supports Point-to-Point, Switched Fabric, and Arbitrated Loop topologies - Two independent Fibre Channel ports - Two SFP sockets accept fiber or copper transceivers - Each port supports 1, 2, and 4 Gbps speeds - Comprehensive decoding of FC-1, FC-2, and Upper Layer Protocol (ULP) frames - Triggering and Filtering - Error Injection on any Header or Payload Parameter - Data Capture to on-board memory or disk file - Live Capture and Current Value Monitoring - IRIG-B Time Code Encoder/Decoder for Data Correlation - In-line Port Configuration for Transparent Analyzer - Supports multiple ULPs including FC-AE-ASM, FC-AE-RDMA, FC-AE-1553, and FC-AV - Supports HS-1760E applications, including AS5653, AS5625, and AS5627fcXplorer Windows-based FC Simulator and Analyzer Test Software
-
product
4 (High Current) D/A Outputs (±40 VDC or +100 mA)
DA3
The DA3 module features 4 high-current D/A output channels with a full-scale range of ±40 VDC or ±100 mA (max). The DA3 provides either voltage or current control loop modes that are programmable for the particular application.