Filter Results By:
Products
Applications
Manufacturers
- Soft Hearts LLC
product
Audio Test Software
1. Distortion free stimulus even the equalized stimulus.2. Unlimited channels acquisition and processing. (Hardware limited)3. Human correlated listening test(Bark Scale intensity chart). (Requires large memory)4. Hi Res intensity chart for buzz/pop detection. (Requires large memory)5. Auto equalization method with target dBSPL accuracy.6. TCP client for test framework integration.7. Easy limits and logs development.8. Easy logs visualization module.9. Auto waveform alignment and triggering.(Upto single point alignment accuracy)10. Easy regression testing via TCP client.11. Standard Magnitude, Phase, THD, THD+N, Rubb&Buzz, Pink Noise, Noise Tests.12. Unlimited calibrations and equalization for scaling to different products and stations.13. Lowest test system and test sequence development times.14. Requires minimal training and debugging.15. Automatically avoid Reference speaker play and stop pops.16. WMD/ASIO driver compatible sound cards supported.(B&K 3670 recommended)
-
product
Detector Test Bench
RTB 3000
The RTB 3000 Detector Test Bench from Santa Barbara Infrared (SBIR) is a flexible integrated IR detector test station for evaluation of single element detectors, linear arrays, and focal plane arrays. The RTB 3000 provides the radiometric stimulus necessary to perform accurate IR detector testing in both laboratory and production environments.
-
product
LASAR Post Processor, Run Time And Diagnostic Test Solution
DtifEasy Series
DtifEasy is a full-featured tool set for importing, converting, and executing IEEE-1445 compliant digital test vectors generated by a LASAR simulation. All four IEEE-1445 file types - UUT model group, Stimulus and Response group, Fault Dictionary group, and Probe group are supported by DtifEasy; providing the user with the ability to execute go/no-go, fault dictionary, and guided probe sequences. DtifEasy supports MTS' 3U PXI GX529x series of dynamic digital instrumentation to 200 MHZ as well as the 6U PXI GX5960, 50 MHz digital instrumentation. All of these instrument families are compatible with the digital logic probe.
-
product
Digital Stimulus Response PXI Card
GX5152
The GX5152 Series are high speed, 6U PXI, digital I/O instruments. The GX5152 master controller has 32 I/O channels that supports test rates up to 50 MHz and vector depths up to 128 Mb per pin. The GX5153 slave offers the same timing characteristics and multiple I/O level configurations when used in conjunction with the GX5152. The GX5152 can control up to 15 GX5153 boards using the same timing and sequencer.
-
product
HV AC Hipot
The HV AC Hipot package is a hardware and software upgrade available for select Eclypse Analyzers. This package adds a High Voltage AC stimulus source CCA to the analyzer chassis and the HV AC Stimulus utility provides the software drives for ELITE to integrate AC Hipot into test programs.
-
product
NI-5741, 16-Bit, 1 MS/s, 16-Channel Signal Generator Adapter Module for FlexRIO
782864-01
The NI‑5741 provides simultaneously sampled analog output channels for signal generation. It also features single-ended, DC-coupled inputs and general-purpose digital input and output lines for system stimulus and control. The NI‑5741 is ideal for applications requiring high-channel density and the power of a user-programmable FPGA. Each channel has a user-configurable sample rate, and data is written directly from the FPGA. To use the NI‑5741, you must pair it with a compatible PXI FPGA Module for FlexRIO.
-
product
Modulation Distortion Up To 43.5 GHz
S930704B
S930704B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 43.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
Digital Stimulus Response PXI Card
GX5152 Series
The GX5152 Series are high speed, 6U PXI, digital I/O instruments. The GX5152 master controller has 32 I/O channels that supports test rates up to 50 MHz and vector depths up to 128 Mb per pin. The GX5153 slave offers the same timing characteristics and multiple I/O level configurations when used in conjunction with the GX5152. The GX5152 can control up to 15 GX5153 boards using the same timing and sequencer.
-
product
ICAP/4 Consumer
Looking to build electronic circuitry and watch its operation right on your computer? ICAP/4 Consumer is an easy to use program that does exactly that. ICAP/4 Consumer enables you to quickly construct any type of analog, digital or mixed analog-digital design, apply electrical stimulus, and view signal waveforms throughout the design.
-
product
Pulse Generators
Keysight Technologies offers the most comprehensive portfolio of stimulus solutions for the generation of digital and analog waveforms and data signals. The Keysight instruments cover a frequency range from 1 μHz to 56 Gb/s and an output amplitude range from 50 mV to 20V.
-
product
RF Sources
Textron Systems’ commercial RF Sources (RFS 340, SSI) provide an unmatched combination of frequency coverage, power range, signal fidelity and switching speed in either a two-slot VXI, 1U LXI®, or VME Synthetic Stimulus Instruments (SSI) format.
-
product
Arbitrary / Function Generators
Today's designs are often complex, demanding a variety of stimulus signals during test. With standard waveforms, arbitrary waveform capability and signal impairment options, a Tektronix Function Generator supports a wide range of application needs with one instrument. Best-in-class Function Generator performance from Tektronix AFGs ensures signals are accurately reproduced.
-
product
Modulation Distortion For E5081A Up To 44 GHz
S960707B
The S960707B modulation distortion software application provides nonlinear DUT behavior tests (EVM, NPR, and ACPR) under modulated stimulus conditions.
-
product
Benchtop Wiring Analyzer
2115
The Model 2115's compact size makes it the ideal choice for many benchtop or portable test applications. The small size does not mean you sacrifice any functionality. The 2115 delivers a full 1500 volt isolation and 2 amp continuity test stimulus. With the optional AC breakdown test providing 1000 VAC test stimulus, you will meet all test requirements.
-
product
64-Channel 500kSa/s USB Modular Multifunction Data Acquisition
U2356A
The U2356A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. With the analog output being able to send out predefined or arbitrary waveforms make this a good tool when closed loop feedback or stimulus is required. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2356A to simulate simultaneous analog input acquisition.
-
product
Modulation Distortion Up To 125 GHz
S930712B
S930712B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S93072B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
PMC and PMC-X Bus Analyzer / Exerciser
PMC850
The PMC850 analyzer provides a multitude of functions to help analyze your system.- Capturing bus activity using sequential triggers and filters- Exerciser to perform memory, I\O and configuration cycles- Stimulus generation for hardware simulation- Target memory with addressable windows- Anomaly detection of protocol and timing violations- Performance analysis of utilization, transfer rates, latency, statistics- Compliance testing
-
product
Modulation Distortion Up To 50 GHz
S930705B
S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
RF Automated Accelerated Reliability Test Station (AARTS)
RF-HTOL
The RF Automated Accelerated Reliability Test Station (AARTS) systems are designed to stress devices with RF, DC, and thermal stimulus. The systems were designed from their inception to include RF stimulus - it was not added as an after-thought. Hence, the software and hardware are fully integrated and provide full-featured support.
-
product
High Volume Manufacturing Handling, Stimulus
ULTRA P
The ULTRA P is a high performance production handler that provides thermal conditioning, full 6 DOF mechanical stimulus and an electrical ATE signal path for testing Micro-Electro-Mechanical Systems (MEMS) Accelerometers and Gyroscopes.
-
product
True-Mode Stimulus
S93460B
The S93460B provides mismatch-corrected true-mode stimulus and enables accurate balanced measurements on 4-port PNA or PNA-X network analyzers.
-
product
Arbitrary Waveform Generator
AWG70000B
The AWG70000B Series Arbitrary Waveform Generator represents the cutting edge in sample rate, signal fidelity and waveform memory, making it ideal for design, testing and operations of complex components, systems and experiments. With up to sample rate of 50 GS/s and 10-bit vertical resolution, it delivers the industry's best signal stimulus solution for easy generation of ideal, distorted and “real-life” signals.
-
product
Chroma LCR Meters
Chroma Systems Solutions, Inc.
Some of the key features to look for in an LCR meter (also known as an impedance meter) are: accuracy, test frequency, measured parameters, test voltage and test current. Additionally, an easy to understand display of test results and the ability to access and use these results has become increasingly important. Component testing often requires much more than simply a resistance, capacitance or inductance value at a given test frequency and stimulus voltage. An LCR meter or impedance meter must have the flexibility to provide multi-parameters over wide frequency and voltage ranges.
-
product
Engineering/Development System
ULTRA L
The ULTRA L is a high performance “Lab” system that provides thermal conditioning, mechanical stimulus and an electrical ATE signal path for testing Micro-Electro-Mechanical Systems (MEMS) Accelerometers and Gyroscopes.
-
product
PXI 8/16-Channel Isolated D/A Converter
M9185A
The M9185A is a fully independent, isolated D/A converter that is capable of supplying high voltage levels in parallel of up to eight or sixteen channels. Each channel is able to output up to 16V as stimulus signals to Device Under Tests (DUTs).
-
product
NI-5742, 16-Bit, 1 MS/s, 32-Channel Signal Generator Adapter Module for FlexRIO
782865-01
The NI‑5742 provides simultaneously sampled analog output channels for signal generation. It also features single-ended, DC-coupled inputs and general-purpose digital input and output lines for system stimulus and control. The NI‑5742 is ideal for applications requiring high-channel density and the power of a user-programmable FPGA. Each channel has a user-configurable sample rate, and data is written directly from the FPGA. To use the NI‑5742, you must pair it with a compatible PXI FPGA Module for FlexRIO.
-
product
ARINC HSI / ADI Test Fixture
TA-2000
The TA-2000 test fixture is a combination panel that incorporates all the standard capabilities of the legacy CTS-11(ADI) and CTS-12(HSI) panels and much more. This panel is married to our model TA-1001 dual synchro transmitter/API panel thus allowing for local stimulus and alignment of the instruments synchros and resolvers. The panel provides for testing of both superflag(28v) and low level meters through a matrix of switching that will allow testing of all meters simultaneously or just individually. The low level meter drive circuit also incorporates an automatic mode that will continuously oscillate the L/R and Up/Dn pointers.
-
product
Electromagnetic Environment Simulators
A2PATS® Products
Our A2PATS Family of Products are electromagnetic environment simulators built upon Textron Systems' open-architecture direct digital synthesizer technology, coupled with our proven user interface. Our easily programmable, plug-and-play modular architecture uses identical, phase-coherent, direct digital Synthetic Stimulus Instruments (SSIs) as the radio frequency (RF) source for all signals. These modular commercial RF Sources are easily configured in our commercial cabinets. Four standard configurations are available including single-cabinet, multi-cabinet, mini-A2PATS, and A2DSG™.The A2PATS Family consists of numerous commercial products including but not limited to A2PATS, A2DRI™, A2DSG and A2EOSTIM.
-
product
PCI and PCI-X Bus Analyzer / Exerciser
PCI850
The PCI850 analyzer provides a multitude of functions to help analyze your system.- Capturing bus activity using sequential triggers and filters- Exerciser to perform memory, I\O and configuration cycles- Stimulus generation for hardware simulation- Target memory with addressable windows- Anomaly detection of protocol and timing violations- Performance analysis of utilization, transfer rates, latency, statistics- Compliance testing
-
product
Digital Wideband Transceiver Analysis
S94610B
Digital Wideband Transceiver Analysis is an add-on software to Device Measurement eXpert (DMX) that adds cross-domain stimulus response measurements for digital/RF mixed-signal device characterization. Included Waveform Creator helps define digital IQ test stimulus waveforms that are used in the RF signal generators for receiver tests or downloaded to the digital-to-analog converters for transmitter tests. The DUT control is customizable to accommodate various data converters and transceiver types by defining device operation settings, transmit/receive switching, reading and writing digital IQ waveform from and to DUTs. Acquired RF or digital data is processed in the VNA’s applications for faster, accurate measurements and analysis.
-
product
Accessories: Test Hardware
Copernicus Technology supply test hardware accessories to support Intermittent Fault Detection testing using VIFD™ and IFDIS™ test equipment, such as Interface Test Adapters (ITA). We also supply and repair general purpose and customer-spec test hardware accessories: ITAs, Break-Out Boxes (shown below) and Mobile Vibration Systems. The Mobile Vibration System can be quickly set up in repair bays for applying environmental stimulus to components and wiring harnesses during testing.