Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI Microwave Transfer Switch, Dual, 26.5GHz, 50Ω, SMA
40-782B-532
The 40-782B-532 (PXI) and 42-782B-532 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
Impedance Meter, Audio, 200Ω, 2KΩ and 20KΩ scales
72-6948
Active device is essential for reliable installation of background music and paging systems in residences, offices buildings and public areas. Avoid costly service calls and amplifier damage by verifying actual speaker system impedance prior to operation. Unlike conventional volt/ohm meters, which measure DC resistance, this unit utilizes an internal 1KHz oscillator to measure true impedance. Accurately measure speaker lines that utilize impedance matching volume controls, switchers, transformers and passive crossovers. Because this unit accurately measures up to 20Kohm, it may also be utilized with 25V, 50V, 70V, and 100V speaker line transformers in commercial installations.
-
product
ABex Terminal Module for Göpel 1149Cx BSCAN Cards
ABex TM-1149Cx
The ABex TM-1149Cx is an ABex terminal module for the Göpel Boundary Scan Controller SFX/PXI(e) 1149/C2/X or SFX/PXI(e) 1149/C4/X. It is connected to the BSCAN-Controller with an adapter-paddle-card.In combination with the above Göpel Boundary scan cards it’s possible to connect up to four JTAG/Boundary Scan TAPs. All signal wires on the PCB are impedance controlled. In addition, all signals can be switched off via relays.
-
product
Impadence Measurement on Multielectrode Arrays
MEArack
Well established in electro-physiological research the standard form factor multielectrode arrays (MEAs) are one of the go-to standards when it comes to impedance measurements on cell cultures.
-
product
Manual Tuners
Manual tuners are used both in the laboratory and as system components to establish or transform impedances for a number of applications. They can be used to establish optimum source or load terminations for device characterization, normalize a source or load for precision laboratory measurements and/or calibrations (noise, power, etc.), and can act as a matching transformer between a mismatched source and a mismatched load.
-
product
Impedance Analyzer
1260A
The model 1260A Impedance/Gain-Phase Analyzer is - without doubt - the most powerful, accurate and flexible Frequency Response Analyzer available today. In daily use by leading researchers wherever measurement integrity and experimental reliability are of paramount importance, the 1260A’s solid reputation is frequently endorsed in published research papers in fields.
-
product
Bus Differential System
B30
The B30 features integrated protection, control and metering for MV, HV and EHV busbars, providing cost effective, feature-focused busbar protection. Use the B30 to protect busbars with up to 6 feeders with up to two three phase differential zones. The B30 is a cost effective alternative to high impedance schemes, ideal for breaker-and-half bus schemes, with integrated feeder backup protection and metering
-
product
General Purpose Basic Carrier Demodulator
CD15
The CD15 Sine Wave Carrier Demodulator operates with variable reluctance transducers to provide a DC output signal for dynamics as well as steady state measurements. A 5kHz sine wave excitation is applied to the two inductance ratio arms of the transducer and the resulting output is demodulated and amplified using the latest integrated circuit techniques. The DC output is obtained from an active filter circuit and gives a uniform response from steady state to 1000 Hz. The low impedance sine wave excitation allows operation with the transducer located over 1,000 feet from the CD15.
-
product
ECT / ECA Eddy Current Flaw Detector
EVi
United Western Technologies Corp
The EVi works directly with the EddyView Family of probes and accessories. UniWest’s unmatched selection of standard and advanced display features set a new standard for flexibility of applications, ease of use, interpretation of data and overall operator accuracy. The key to the EVi’s ground-breaking performance is the display of a visual image of the surface area under inspection alongside the customary and selectable eddy current signal displays (impedance plane, A-scan or strip charts). The EVi provides a high precision, easily readable display of surface conditions enabling improved interpretation of data while giving more accurate discernment of cracks, pits, gouges and fretting.
-
product
PXI Single SP6T MUX 6GHz 50Ω SMA
40-784-001
Pickering Interfaces’ 40-784 PXI Microwave Multiplexer Modules have a characteristic impedance of 50 Ohm and are capable of switching signals up to 40GHz. Available in single or dual SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
Impedance Analyzer / LCR Meters
When used together with the PSM range of frequency response analyzers, the N4L impedance analysis interfaces provide a measurement solution to many impedance analysis applications. The most appropriate interface for a specific application will depend upon the nominal impedance of the sample or device being tested and the frequency of measurement and N4L will be happy to discuss the optimum soution to any application. Reasons to choose an N4L Impedance Analyzer
-
product
Differential Probe
DP-16V
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-50MHz*Input Impedance 30MΩ// 1.5PF*x20, x200, x2000 Attenuator*To Ground MAX. Voltage: 8KV CAT III*Output Impedance 50Ω
-
product
Preconfigured Latching, Transfer Switch, 50Ω impedance, SMA Connectors, DC-26.5GHz
Part No. ECS-37S
Preconfigured Latching, Transfer Switch with SMA connectors, 50Ω impedance DC-26.5GHz
-
product
Circulators
Our Millimeter Wave Circulators are the most advanced on the market today. We use sophisticated impedance matching and mode controlling techniques to provide the widest bandwidth in the industry. We have developed a new wideband hybrid circulator technology. The hybrid circulator has significantly higher bandwidth than the Y-junction. The hybrid circulator is an enabling technology for broadband transmit/receive applications.
-
product
Matching Network Solution
Navio
Experience simplicity and high reliability in a single, affordable package. The Navio™ matching network leverages our power expertise to precisely match complex plasma impedance to your tuning range. It’s quick, accurate, and repeatable. Available in multiple power ranges and frequencies, choose from a standard offering or a configurable design. Installation is virtually plug-and-play with Advanced Energy’s RF power supplies. Virtual Front Panel software is available for monitoring.
-
product
N1.2 Calibration Kit
N1.2 Calibration Kit, Frequency Range: up to 1.5 GHz, Impedance: 50 Ohm Connector Type: N-type
-
product
LISN Line Impedance Stabilisation Networks / AMN Artificial Mains Network
A LISN Line Impedance Stabilization Networks / AMN Artificial Mains Network: *supplies the neccessary mains voltage (AC or DC) and current for the Equipment under Test (EuT).*couples interference voltage generated by the EuT and supplies it to the receiver.*provides well defined RF-impedance to the Equipment under Test (EuT)*keeps away unwanted disturbance coming from mains (filter)*protects the mains from unwanted disturbance voltage generated by the EuT
-
product
Latching (Terminated) SP4T or SP6T Multi-Throw Switch, 50Ω Impedance, 2.4mm Connectors, DC-52GHz
Part No. CCT-39U
Latching SP4T or SP6T Multi-Throw switch, 50Ω impedance. Includes internal 50Ω terminations on unused ports. Available in Commercial and Elite models, with 2.4mm connectors.DC-52GHz
-
product
32-CH Discrete Input Daughter Board Module
HSL-DI32-DB-N
*Slave ID consumption: 2 - N: for 32-CH NPN sinking type sensor inputs or dry contact*Photo couple isolation voltage: 2500Vrms*Input impedance: 4.7KΩ*Input current: ??10mA (Max), ??12.5mA (Peak)*Input voltage: ??40V (Max)
-
product
PXI/PXIe Microwave Transfer Switch, Dual, 50 GHz, 50 Ω, SMA-2.4, Failsafe, Remote Mount
42-782B-552-E
The 40-782B-552-E (PXI) and 42-782B-552-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 50 GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
product
Failsafe, Normally Open (Non-Terminated), SP3T, SP4T, or SP6T Multi-Throw Switch, 50Ω Impedance, SMA Connectors
Part No.s CCR-38S/CR-38S SP3T/SP4T/SP6T
Normally open, SP3T, SP4T, or SP6T Multi-Throw switch, 50Ω impedance Available in Commercial and Elite models, with SMA connectorsDC-18GHz (commercial - CCR) DC-22GHz (Elite - CR)
-
product
Impedance Analyzers
1MHz to 300MHz Measurement Frequency Impedance Analyzer with 0.5ms Test Speed and Superior Repeatability
-
product
High Speed Phase Inverter - Buffer
WMA-IB-HS
The WMA-IB-HS can be used to double the output voltage of two high voltage amplifiers by driving them in bridge mode, or as high impedance input buffer while maintaining precision, high speed and low noise. Because of its high bandwidth, the WMA-IB-HS model is ideal for the Falco Systems WMA-100 or WMA-300 amplifiers. It can also be used with all other Falco Systems HV amplifiers, or even with high voltage amplifiers of another brand.
-
product
Battery Test Equipment
KV Hipot Power Test Equipment Co.,Ltd
Battery testers are the class of instruments designed to assess the condition—the charge, impedance, ripple current, or other measurement—of batteries to ensure they are working as required. Just as batteries have a very wide range of sizes and uses, so do battery testers.
-
product
Mechanical Noise Tuner Control
S93027B
The S93027B enables to control Maury Microwave’s LXI tuner as the impedance tuner and measure the noise figure of unmatched devices (Gamma opt. < 0.9) with the N524xB PNA-X with option 029 and the S93029B noise figure measurement software.
-
product
Bench/portable Universal Counters With USB Interface 3GHz Or 6GHz
TF900 Series
Frequency, period, pulse width, frequency ratio, duty cycle, and event counter modesDC to 3000 or 6000MHz range, 0.001mHz resolutionHigh impedance measurement up to 125 MHzAC or DC coupling, 1M/50Ohm selection, polarity invertSwitchable attenuator, threshold controlNoise filter for low frequency measurementsSelectable measurement time; display hold functionLarge 10 digit display with full range of annunciatorsInternal rechargeable batteries for portable useUSB interface provides full remote control and readback
-
product
Full Performance and Flexibility on ECIS 8 Well Arrays
Sciospec ECIS Adapter
The ECIS CULTUREWARE 8 well arrays are a very common choice for a broad range of impedance-based cell experiments like cell groth, cell migration, wounding/healing, barrier function, tox-screening, adhesion and proliferation studies. With the Sciospec ECISadapter you can bring your ECIS experiments to the next level: more speed, higher resolution, more possibilities. Harness the full power of Sciospec impedance analyzers on your existing ECIS arrays. The ECISadapter just plugs into compatible Sciospec impedance analyzers like the ISX-3 and you´re good to go.
-
product
Microphone Preamps
Applied Research and Technolgy
Unlock your mic's full potential with advanced features like variable impedance, mid-side processing, and real tube warmth.
-
product
Mini Coax, Contact, ITA, RG178
610103130
Primary mating contact 610104141. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 milliohms @ 0.5 Amp & always < 10 milliohmsCable Specifications RG178Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.