Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI Source Switching Module
40-618A-001
The 40-618A PXI Source Switching Module consists of 12 separate 4-channel multiplexers and 44 uncommitted SPST relay contacts in a single width PXI module.
-
product
Sound Power Reference Source
Qref
Precision omni-directionallity in all directions, horizontal and vertical plane. This source has a frequency range of application between 100 and 8000 Hz (third octave bands) Despite only weighing 1.4 kg and having a diameter of 105 mm, it produces a maximum sound power level of Lw 104 dB.
-
product
4-Channel ADC FMC Module
FMC103 – LPC
Sundance Multiprocessor Technology Ltd.
The FMC103 is a four-channel ADC FMC (FPGA Mezzanine Card) which is fully compliant with the VITA 57.1-2010 standard. The FMC103 card provides four 12-bit 210 MSPS A/D channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC103 has the LPC (Low-Pin Count) 160-Pin connector, front panel I/O, and is conduction cooled compliant. The board is also available with Mil-I-46058c compliant Conformal Coating.
-
product
2-Channel DAQ Module
FMC151
Sundance Multiprocessor Technology Ltd.
The FMC151 is a dual channel ADC and dual channel DAC FMC daughter card. The card provides two 14-bit A/D channels and two 16-bit D/A channels which can be clocked by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition there is one trigger input for customized sampling control. The FMC151 daughter card is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).
-
product
Coherent Modulation Transmitter
IQTX
Generating and controlling phase modulated optical signals is easy with the IQTX. The IQTX is referred to as a ‘Golden’ reference optical signal source because of its high repeatability and reliability.Its high bandwidth of 40 GHz ensures high quality optical signal generation, making it the ideal optical signal source for coherent communications applications.
-
product
PXIe Frequency Reference: 10 MHz And 100 MHz
M9300A
The M9300A PXIe frequency reference is a PXIe-compatible, compact, modular instrument that can be used with the Keysight M9301A synthesizer, M9310A source output, and M9311A modulator to create the world’s fastest vector signal generator, the M9381A. Create a CW source, the M9380A, by combining the M9300A with the M9301A and M9310A or use it as the 10-MHz or 100-MHz reference with other PXI solutions. Control the instrument through a soft front panel and programmatic interfaces tuned to your application development environment of choice.
-
product
IR Calibration Instruments
Bodkin Design & Engineering, llc
We offer a line of comprehensive solutions to address all of your thermal calibration needs. From bench-top differential sources with .01° C resolution for experiment calibration to built-in OEM devices for on-the-fly thermal reference, Bodkin Design and Engineering and IRBlackbody have the right blackbody for you.
-
product
PMC-Parallel-IO
PMC-Parallel-IO provides 64 independent IO in one PMC slot. 64 mA open drain buffers on each IO. Two interrupt sources. External or internal clock reference. Custom state machine designs.
-
product
Mezzanine System
5174
The 5174 provides two major functions, serving as a precision Voltage Controlled oscillator board and a variable frequency source board. These features can be use together or independently. As a variable frequency source, the 5174 provides a high-resolution variable clock source that is based upon a reference clock supplied by the ECM carrier.
-
product
Thermal Software
ThetaCalc
Thermal Engineering Associates, Inc.
A tool designed to provide a quick estimate of the temperature and thermal resistance from a heat source to a reference heat sink. It also shows the temperature and thermal resistance value of each layer in the heat flow path. The program can accomodate up to ten layers of different materials of varying dimensions between the heat source and sink. The heat spreading angle can be set independently for each layer to a value between 0 and 45 degrees; the tool will automatically determine if heat flow reaches the layer edge and then convert to columnar flow.
-
product
Code Coverage Branch Monitor
CCBM
Verified Systems International GMBH
The Code Coverage Branch Monitor (CCBM) is a set of utilities that allow instrumentation of C source code for the purpose of branch coverage measurement. This encompasses operations for code instrumentation, removal of this instrumentation, retrieval of coverage information, merging coverage information, and displaying this information with reference to the (original) source code.
-
product
CN-37 Blackbody
Compact thermal camera reference source. Compatible with all thermography cameras on the market and IEC 80601-2-59 compliant. Available now, ready to ship.
-
product
Reference Transmitter
81492A
Keysight's 81492A Reference Transmitter is designed to offer excellent eye quality for NRZ and PAM4 signals at baud-rates up to 56 Gbaud and can serve as universal single-mode E/O converter. In addition to the internal lasers at 1310 & 1550 nm, an external optical input for usage with tunable laser sources is available. It is fully integrated into Keysight’s Optical Receiver Stress Test solutions to address test requirements of IEEE 802.3 10,40,100 and 400GBASE optical standards.
-
product
Mini Light Source Meter
MLS-100
•Stabilized Light Source•1310nm & 1550nm•Very small and lightweight•Controlled by Smartphone or PC via USB or Bluetooth•Smartphone application software and PC software•Li-ion Polymer Rechargeable battery•Battery charging via a USB interface•Universal 2.5mm adapter to accept FC, SC or ST•Reference light source for optical test
-
product
Industrial Calibrators
A temperature calibrator, often called a thermometer calibrator, is used to correct inaccuracies in installed thermometers and temperature sensors, because temperature measurement is a critical parameter in many industrial processes. Although simulators are sometimes called temperature calibrators or thermometer calibrators and may be used to provide thermometer calibration for the electronics in an installed system, a temperature source with a calibrated reference sensor is still required to provide a complete and meaningful calibration. Fluke Calibration industrial and field temperature calibrators include: Metrology Wells; Field Metrology Wells; field dry-well calibrators; handheld dry block calibrators; Micro-Baths; large target infrared calibrators; field IR calibrators; ice-point dry-well; and thermocouple furnaces.
-
product
Time Code Generators
Masterclock's time code generators provide a source of very stable time code and accurate time and date information. The GPS500 extracts timing reference from GPS satellite signals and generate time code synchronized to within less than 10 microseconds of UTC (Universal Coordinated Time). It can output IRIG-B with and without IEEE 1344 date encoding, SMPTE/EBU, NMEA 0183, Kinemetrics/Truetime, and 1PPS.
-
product
GPS Master Clock
Signals & Systems India Private Limited
GPS Master Clock System – MCS-GPSMC-1010 is a 3U Card rack type, 19” Rack-mountable Redundant GPS Time Server which synchronizes and maintains the timing and frequency requirement of power and process industry equipment using a signal obtained from any one of the sources like GPS or GLONASS or Time protocols such as NTP and IRIG. It distributing the same time signal through several types of interfaces. It provides redundancy for Power and GPS receiver to increase reliability and offers protection against time synchronization failure. The system is field-upgradeable and an extremely flexible system, designed to handle time synchronization requirements today and in the future. It provides nanosecond accuracy when external time references are not available. It has a storage facility to store the system log file. It delivers NTP, SNTP, IRIG-B, PFC-Pulse, DCF77, BCD parallel data, Ethernet Fiber Optic & RS485/RS232 outputs. System enables configuration and monitoring through Web-based application. It supports a wide range of power supply either 90V-260V AC/DC or 18-36VDC or 36V-72VDC. Power supply model can be mixed and matched as required by the user, depending upon power supply options available at the installation site.
-
product
Pt RTD Temperature Monitor
SIM923
Stanford Research Systems, Inc.
The four channels in the SIM923 have independent, stable 1 mA current sources to provide sensor excitation. Sensor resistance is determined ratiometrically with a half-bridge circuit consisting of the sensor and an internal reference resistor.
-
product
FPGA Mezzanine Card
FMC160
The FMC160 provides one 12-bit A/D channel at 3.6Gsps and one 14-bit D/A channel at 5.7Gsps (2.85Gsps direct RF synthesis) clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users. It is mechanically and electrically compliant with the FMC standard (ANSI/VITA 57.1).
-
product
FPGA Mezzanine Card
FMC216
The FMC216 is a 16-channel DAC FMC daughter card which is fully compliant with the VITA 57.1-2008 standard. It provides 16 D/A 16-bit 312.5Msps (2.5Gsps with x8 interpolation) channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available.
-
product
Load Cell Power Supply
MODEL PSMR
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.
-
product
RF Reference Source
96040A Series
The 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system.
-
product
Spectral Response SystemsQuantum Efficiency SystemsIPCE Measurement Systems
QE system provides electronics and software designed for fully automated measurement of external quantum efficiency of solar cells. All systems include probes and a fixed plate sample stage for samples up to 150 mm x 150 mm. The main system components include: custom designed software, measurement electronics, and computer system (Windows 8 operating system). The measurement involves focusing monochromatic light to a spot on the device under test, then accurately measuring the photon flux and current from the test cell. The system utilizes a dual beam configuration with lock-in detection, providing an absolute accuracy of ±3%. The QE system uses a grating monochrometer with silicon/InGaAs/Ge detectors. The system includes automatic order sorting filters and two light sources for monochromatic illumination (a Xenon- arc lamp and a halogen lamp). A single lock-in amplifier is used to measure both the reference detector and test device. The main system comes with all the hardware needed to measure quantum efficiency, a fixed plate sample stage and probes.
-
product
Video Transmitter
Model: DS-5210
The S-Band Video Transmitter is a synthesized microwave signal source providing low phase noise with a high level signal output. The unit can be set to any frequency within the band of design via a USB or RS-232/422/485 computer command. The oscillator is phase locked to an internal TCXO reference. The oscillator pro-vides a stable low noise source for video transmission.
-
product
Multi Channel Optical Fibre Verification
The multi-channel optical fibre test system is used in the development and qualification of single mode optical fibres. The fibres are exposed to environmental influences in a climatic chamber in order to analyse the data on insertion loss and reflection. In addition, the current temperature in the climatic chamber is documented. Insertion loss measurement is performed with the help of an optical power meter, laser sources and optical switches. An Optical Time Domain Reflectometer (OTDR) from Exfo is used for the reflection measurements. The system was designed for the simultaneous characterization of 15 sample fibres and one reference fibre.
-
product
10 MHz AGC Distribution Amplifier
FS710
Stanford Research Systems, Inc.
For installations which require many 10 MHz outputs at a remote location from the source, the FS710 AGC Distribution Amplifier offers seven independent outputs from one input. With an AGC circuit capable of adding up to 30 dB of gain, this amplifier can be used to provide a 10 MHz reference at locations as far as a mile from the source.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
Primary Standards
Primary standards (often also referred to as mechanical dead-weight testers, pressure balances or primary pressure standards) are the most accurate reference instruments for pressure. Their functional principle is based on the physical principle of pressure = force/area. Mass pieces placed on the top of a piston-cylinder system are the source of a precisely defined force. By producing a certain (counter) pressure inside the primary standard an equilibrium is achieved: the mass pieces, including the free-running piston of the piston-cylinder system, are floating, which will lead to a very accurate pressure at the test port which measured through piston gauge technology.
-
product
FMC-HPC ADC Board
FMC123
Sundance Multiprocessor Technology Ltd.
The FMC123 provides four 16-bit A/D channels up to 1Gsps. The design is based on Texas Instruments’ ADS54J60 Analog-to-Digital converter. The sample clock can be supplied externally through a coaxial connection or supplied by an internal clock source (optionally locked to an external reference) for multi-channel synchronization. An external trigger input is available for timing synchronization. The FMC123 is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).
-
product
1000W Ferroresonant Power Supply
Series PRR
Kepco's PRR are 1000 Watt rack mounted laboratory systems power supplies that offer the low cost and very high dependability of ferroresonant voltage stabilization.The ferroresonant stabilizing technique provides extraordinary isolation from a wide variety of source noise. It is inherently short-circuit proof and cannot expose delicate loads to overvoltage hazards. Hence no crowbar, fuses, or bounding circuits are needed. Ferroresonant power supplies use no noise-producing switches or oscillators. Voltage setting is independent of delicate control settings or diode references and requires no comparators, references, or limiters. Efficiency is 70-80%.