ROSS ENGINEERING CORPORATION of Campbell, California, designs, tests and manufactures High Voltage Relays, High Voltage Probes, and High Voltage Voltmeters.
- (408) 377-4621
- info@rossengineeringcorp.com
- 540 Westchester Drive
Campbell, CA 95008
United States
-
product
HV Calibration
B-1027
Ross Engineering Corporation’s High Voltage Calibration Lab provides high accuracy capability for conducting tough reliability tests on all our high voltage devices. In this facility we test and calibrate HV Relays, HV Dividers, HV Probes, Spark Gaps, our Fiber Optic Systems, and HV Digital Voltmeters up to 450kV. We provide our own in house test lab to ensure Ross products meet or exceed required safety standards as well as our own high standards of dependability, long life and quality. Our technicians use test equipment calibrated by or traceable to National Institute of Standards and Technology or other national metrology institute to provide the highest in testing accuracy.
-
product
Hi-Z Probes
B-1012-B
High Voltage Probes for Very Low Current Power Supply Voltage Measurementto 120kV, such as Electrostatic Paint Spray Applications...
-
product
HV Spark Gaps
B-1015
*Spark gaps are enclosed in dust tight transparent enclosures with replaceable non-melting carbon spheres, up to 88kV PK.*Above 88kV, open style with hollow aluminum spheres is standard.*Applications for these units include over-voltage limiting, voltage measurement, capacitor discharge, and pulse forming.*Horizontal unit housings are removable.*Vertical unit housings are not removable.*Micrometer Vernier adjustment is standard for maximum accuracy on most models. Economy units without micrometer Vernier adjustment are available as an option.*Insulation to ground is available at standard and optional levels.*Spark gaps to 370kV, with motor operation available.
-
product
Step Start Systems
B-1009
The Step-Start Vacuum Circuit Breaker/ Power Controller is designed for extra heavy duty repeated fault, crobar and load interruption for sensitive equipment. It is designed to limit initial closing inrush current to approximately load or other maximum current with an adjustable step delay.
-
product
High Current Switches
B-1002
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
product
Hi-Z HV Safety Voltmeters
B-1013-4
These Hi-Z® HV Safety Voltmeters are for Power Lines, Electric Cars, Electric Trolley and other High Voltage AC & DC detection and measurement. Emergency Crews can use these voltmeters to detect voltage presence warning. They will accurately measure AC and DC voltages.
-
product
HV Test Load Systems
B-1025-1
Design and manufacture of electronic and electromechanical devices and systems for our customers' special applications has been Ross Engineering Corporation's specialty for 44 years. Among these devices are our High Voltage Test Loads and Resistance/Capacitance Networks designed to simulate radar, communication, and television transmitter loads for testing up to 300kV DC or AC and 200kW. For example, one Test Load System required 4 separate simulated load networks to complete an 8kV, 14kV, 24/6kV, and 34kV high voltage testing system.
-
product
Voltage Level Sensor / Interlock
B-1011-G
For limiting, setting or indicating voltage levels of power supplies, required charge level for energy storage capacitors, and voltage level interlocking.
-
product
Coaxial Cable Drivers & Amplifiers
B-1020
*Wideband: DC to over 30MHz*Maximum Output: to 10V PK, 20V PK-PK*Maximum Input: ±5V to ±200V PK-PK as required. Also to 900kV PK with Ross Voltage Divider*Signal Isolation: 500,000 Ohm 450V PK*Input Impedance: Up to 2 Megohms*Load Impedance: 50 Ohm or greater*Power Source: AC or Optional Battery*Will drive over 500 Feet of Coaxial Cable
-
product
HV Reed Relays
B-1001-H
*5kV to 15kV Peak Test*3A Continuous*50VA Max Interrupt*NO, NC, DT, Single & Multi-Pole*Safety Encapsulation*HV Leads Available*Compact *Long Life*High Vibration / Shock Resistance*Maximum Creep distance between HV & Actuators Terminals *Tapped base, Turret or Hook terminals, PC Board mounting, Quick disconnect or HV leads available
-
product
HV Probes & Multimeters
B-1010, B1010-A, B-1012, B-1012-A
HV Probes and Voltmeters for oscilloscopes, DVMs, recorders. HV DC, AC & Wideband DC-10MHz. Safety probes for any scope, digital display or recorder. Also available complete with large 4½ digit display 0.01% to 5% DC/AC accuracy digital voltmeter, with safety handles for OSHA recommended personnel clearances. With attached or separate digital display or multimeter 0.00001V to 400kV. HV Digital Multimeters. Wideband DC-10MHz. VMD2A 4½ digit portable meter has accuracies to 0.01% DC, 0.1% 50/60Hz, 3% DC-1MHz, 3dB to 10MHz. True RMS, Avg, True +PK, -PK, PK to PK, 0.2 microsecond, 1/2 sine single pulse capture & hold. 0.00001V - 1000V DC or PK AC and for use with HV Probes to 400kV and Voltage Dividers to 1,000,000V. Has 2V output to scope, recorder. To 1000kV with HV divider, DC-10MHz.
-
product
HV Voltage Dividers
*DC up to 10MHz*1kV to 1,200kV DC or PK AC*To 1,875kV Impulse*To ±0.01% DC Accuracy Accredited*To ±0.2% AC Accuracy (50/60Hz) Accredited*To ±3% DC-1MHz Wideband*±3dB 5 to 30 MHz*Compact & Lightweight*For Oscilloscopes*For Recorder*For Digital Multimeters*Very Partial Discharge/Low Corona*Very Low Phase Shift*Resistive*Capacitance*Compensated Wideband*Indoor & Outdoor*Electronic and Power Class*Match Wideband Differential*High Voltage Power Quality Instrumentation
-
product
Three-Phase HV Vacuum Contactors & Circuit Breakers
B-1005/6
*Three Phase*Upright or Low Profile for High Reliability*½ to 2 Cycle Trip & Interrupt*208V to 38kV Operate*200 to 1,200A Continuous*2,000 to 28,000A Interrupt*Line or Energy Storage Close & Trip*Ideal for High Power Electronics*High Speed Sealed Arc Interrupting*High Speed Crobar Shorting*Compact, Light Weight*Long Life*Minimum Reignitions*Minimum Restrikes
-
product
HV Megmeter
B-1013-6
Ross Engineering Corporation’s High Voltage Megmeter® series are unique battery powered DC hipot tester and meter. Models are available for withstand testing of insulation up to 50kV DC, as well as measuring leakage current as low as 0.001 microamp and resistance as high as 30 million megohms when testing underground cable, rubber safety gloves, vacuum interrupters, high voltage devices and all types of electrical insulation. All models have an over current trip feature to minimize arcing damage. Completely portable with rechargeable 12V battery which can be recharged from an automobile or 115V, 230V AC.
-
product
Hi-Z HV AC Voltmeters
B-1013
*25kV, 50kV or 100kV Meter with integral line to ground Probe*Phasing or line to line with additional Probe*Optional 6ft or 9ft Collapsible Hotsticks*Voltage source for testing Voltmeters and Probes*Optional test point contamination indicating Megmeter®*High voltage cable clamps or hooks*Heavy duty carrying case