Teledyne Advanced Pollution Instrumentation
Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.
- (858) 657-9800
- (858) 657-9818
- api-sales@teledyne.com
- 9970 Carroll Canyon Road
CA, San Diego 92131
United States
-
product
Process Ozone Sensor
Model 452
Teledyne Advanced Pollution Instrumentation
The Model 452 is a microprocessor based gas sensor for measuring high concentrations of ozone in oxygen or air with accuracy and dependability. The measurement principle is based on the absorption of UV light at 254nm. Readings are available in % by weight, or grams/Normal cubic meter. Temperature and pressure compensation up to 3 Bar Absolute is a standard feature.
-
product
UV Fluorescence SO2 Analyzer
Model N100
Teledyne Advanced Pollution Instrumentation
The Model N100 instrument uses the proven UV-fluorescence principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Sulfur Dioxide (SO2) gas.
-
product
UV Fluorescence TRS Analyzer
Model T102
Teledyne Advanced Pollution Instrumentation
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
-
product
Gas Calibrators and Zero Air Generators
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
product
Compact Ozone Monitor
Model 430
Teledyne Advanced Pollution Instrumentation
Teledyne API, a recognized leader in Ozone measurements, is pleased to offer the Model 430 O3 Monitor. The 430 is a compact instrument that uses the proven UV-absorption principle. The small footprint and robust design make it ideal for a variety of applications where portability and accuracy are both necessary.
-
product
Photolytic True NO2/NO/NOx Analyzer
Model T200P
Teledyne Advanced Pollution Instrumentation
The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.In the photolytic process the sample gas passes through a cell where it is exposed to light at a specific wavelength from an LED array. This causes the NO2 to be selectively converted to NO with negligible interference from other gases. Advances in the photolytic converter technology now yields NO2 conversion efficiency that is similar to molybdenum under typical ambient NO2 concentrations, but without the same interferences.
-
product
High Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200H
Teledyne Advanced Pollution Instrumentation
The Model T200H combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. A high-efficiency stainless steel thermal NO2 converter provides durable and consistent operation under the harshest conditions (other converter options also available).The T200H may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.
-
product
Process Ozone Instruments
Teledyne Advanced Pollution Instrumentation
All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring. Below is a list of a range of Teledyne API process ozone instruments.
-
product
Nitrogen Compound Instruments
Teledyne Advanced Pollution Instrumentation
Teledyne API produces a wide range of instruments for the measurement of Nitrogen compounds, including those that measure 'True NO2'. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring
-
product
THC-CH4-NMHC Analyzer
Model N901
Teledyne Advanced Pollution Instrumentation
The Model N901 is a near-continuous hydrocarbon gas analyzer that measures the concentration of Methane (CH4) and Total Hydrocarbons (THC) in air. The concentration of the non-Methane (NMHC) component is calculated by the subtraction of CH4 from THC, with high sensitivity and accuracy. The hydrocarbons are measured using a Flame Ionization Detector (FID), in combination with gas chromatography (GC). The instruments range and performance are tuned specifically for use in ambient air quality monitoring assessments.
-
product
Trace Level Portable Gas Calibrator
Model T750U
Teledyne Advanced Pollution Instrumentation
The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.
-
product
Single/Multi-Channel Industrial Safety Ozone Monitor
Model 465L
Teledyne Advanced Pollution Instrumentation
The Model 465L UV Photometric Ozone Monitor is an extremely stable analyzer, ideal for critical low-level ppm safety and process applications. Its calibration is NIST traceable and the included pressure and temperature compensation ensure high accuracy under all conditions.
-
product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
product
Total Sulfur Analyzer
Model T108
Teledyne Advanced Pollution Instrumentation
The Model T108 Total Sulfur analyzer is designed to measure mixed sulfur impurities, collectively referred to as Total Sulfides, in air or carbon dioxide gas. Since there is no scrubber in the system, the instrument reading is the sum of the oxidized sulfur compounds and SO2.The Model T108 consists of a modified Model T100 SO2 analyzer with special software and a Model 501TS high temperature thermal oxidizer. Sulfur compounds are heated as they pass through the converter and oxidized into SO2. When analyzing CO2, which generally contains no oxygen, approximately 6% O2 is added to the sample before entering the converter. This dilution is corrected in the calibration procedure.
-
product
Gas Filter Correlation CO Analyzer
Model N300
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.